MUCHR-H6 Series

Commercial range

20 a 26kw

Models 20 to 26

40 a 45kw

Models 40 and 45

High capacity duct inverter MUCHR-H6 Series

Characteristics

  • DC Inverter Compressor
  • Accurate temperature control
  • High static pressure
  • Parameters check function
  • Built-in wired remote control with temperature sensor (KJR-29B)

     Technical Documentation

Data SheetES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
Owner's manualES 18X18EN 18X18
Indoor Unit Installation manual up to 26kWES 18X18EN 18X18
Indoor Unit Installation manual 40 & 45kWES 18X18EN 18X18
Outdoor Unit Installation manual up to 26kWES 18X18EN 18X18
Outdoor Unit Installation manual 40 to 45kWESEN

TECHNICAL SPECIFICATIONS

 

ModelMUCHR-20-H6MUCHR-22-H6MUCHR-26-H6MUCHR-40-H6MUCHR-45-H6
CodeCL23904CL23905CL23906CL23912CL23913
Cooling (1)CapacitykW19,6622,5325,9538,9643,95
kcal/h16.91019.37822.32033.50937.801
ConsumptionkW6,97,68,414,616,3
EERkW/kW2,852,963,092,672,7
Heating (2)CapacitykW19,8622,1825,7841,3545,38
kcal/h17.08219.07722.17435.56539.031
ConsumptionkW6,96,78,413,815,4
COPkW/kW2,883,313,0732,95
Indoor unitModel MVD-200T1/DHN1-B250T1/DHN1-B280T1/DHN1-BD400T1/N1-FD450T1/N1-F
CodeCL23381CL23382CL23383CL23187CL23188
Power supplyF, V, Hz1N-, 220-240V, 50Hz
Rated CurrentA66612,512,5
Air flow (H / M / L)m3/h4820 / 4660 / 46204820 / 4660 / 46204820 / 4660 / 46207474 / 6072 / 49957474 / 6072 / 4995
Static pressure avail. (ESP)Pa62 (40 – 200)62 (40 – 200)62 (40 – 200)200 (50 – 280)200 (50 – 280)
Sound pressure (H/M/L) (3)dB(A)57 / 53 / 5057 / 53 / 5057 / 53 / 5061 / 59 / 5661 / 59 / 56
Dimensions (W x H x D)mm1450 x 505 x 9251450 x 505 x 9251450 x 505 x 9251970 x 668 x 902,51970 x 668 x 902,5
Weightkg108108108232232
Drain connectionmm3232323232
Power cable (5)mm22 x 2,5 + T2 x 2,5 + T2 x 2,5 + T2 x 4 + T2 x 4 + T
Outdoor UnitModel MVD-V200W/DRN1V224W/DRN1V260W/DRN1V400W/DRN1V450W/DRN1
CodeCL23269CL23270CL23271CL23272CL23273
Power supplyF, V, Hz3N-, 400V, 50Hz
Rated CurrentA14,516,218,73344
Air flow (H)m3/h10.99910.49410.49416.57516.575
Static pressure avail. (ESP)Pa00000
Sound pressure (4)dB(A)5959606262
Dimensions (W x H x D)mm1120 x 1558 x 4141120 x 1558 x 4141120 x 1558 x 4141360 x 1650 x 5401460 x 1650 x 540
WeightKg137147147240275
Power cable (5)mm24 x 6 + T4 x 6 + T4 x 10 + T4 x 25 + T4 x 35 + T
RefrigeranteTypeR410A
Preloaded amountkg4,86,26,2912
Additional load (from 0 m)kg/m0,0570,0570,0570,110,11
Pipe connectionsLiquid Linemm (")9,52 (3/8")9,52 (3/8")9,52 (3/8")12,7 (1/2")12,7 (1/2")
Gas Linemm (")19,1 (3/4")22,2 (7/8")22,2 (7/8")28,6 (1 1/8")28,6 (1 1/8")
Pipes distances (6)Max. Verticalm2525252525
Totalm606060100100
Communication cablemm23 x 0,75 (Shielded)
Wired controllerModelKJR-29B
TypeWired
Temp. range performanceCoolingºC-15 to 43-15 to 43-15 to 43-5 to 43-5 to 43
HeatingºC-15 to 24-15 to 24-15 to 24-15 to 24-15 to 24

Notes:

(1) Nominal cooling conditions: Indoor 27 °C DB, 19 °C WB and outdoor 35 °C DB, pipe length of 8 m and a height difference of 0 m.

(2) Nominal heating conditions: Indoor 20 °C DB, 15 °C WB and outdoor 7 °C DB, pipe length of 8 m and a height difference of 0 m.

(3) Noise level measured in semi-anechoic chamber at 1m front distance and 1.4 m height.

(4) Noise level measured in semi-anechoic chamber at 1m front distance and 1.2 m height (1.3 m for 20-26 kW models)

(5) Power wiring recommended for L < 20 m, for longer distances it should be calculated.

(6) Pipe length when the outdoor unit is lower installed than indoor units. Otherwise, see part MVD.

The above design and specifications are subject to change of product improvement without prior notice.

Caution:

Before starting up the equipment (and without supply), you have to configure the whole micro-switch S6 in OFF position in the outdoor unit.