Commercial range
Model | MUCR-12-H6 | MUCR-18-H6 | MUCR-24-H6 | MUCR-30-H6 | MUCR-36-H6 | |||
---|---|---|---|---|---|---|---|---|
Code | CL20250 | CL20251 | CL20252 | CL20253 | CL20254 | |||
Cooling | Nominal capacity (min. - max.) | kW | 3,52 (0,62 ~ 4,40) | 5,28 (0,79 ~ 6,15) | 7,03 (1,20 ~ 8,21) | 8,79 (2,08 ~ 10,55) | 10,55 (2,93 ~ 12,02) | |
Nominal consumption (min. - max.) | W | 1.030 (210 ~ 1.690) | 1.685 (260 ~ 2.365) | 2.285 (400 ~ 3.155) | 2.875 (690 ~ 4.055) | 3.965 (975 ~ 4.620) | ||
Nominal current (min - máx) | A | 4,7 (1,0 ~ 7,7) | 7,7 (1,2 ~ 10,80) | 10,4 (1,8 ~ 14,4) | 13,1 (3,2 ~ 18,5) | 18,1 (4,2 ~ 20,1) | ||
Pdesignc | kW | 3,5 | 5,3 | 7,0 | 8,8 | 10,5 | ||
SEER | W/W | 6,1 | 6,5 | 6,1 | 6,1 | 6,3 | ||
Energy labelling | A++ | A++ | A++ | A++ | A++ | |||
Heating | Nominal capacity (min. - max.) | kW | 3,81 (0,62 ~ 4,98) | 5,57 (0,88 ~ 7,03) | 7,03 (1,20 ~ 8,65) | 9,38 (2,08 ~ 10,84) | 11,13 (2,64 ~ 13,19) | |
Nominal consumption (min. - max.) | W | 995 (496 ~ 1.790) | 1.460 (290 ~ 2.510) | 1.900 (400 ~ 3.090) | 2.460 (690 ~ 3.870) | 2.923 (880 ~ 4.690) | ||
Nominal current (min - máx) | A | 4,5 (2,3 ~ 8,2) | 6,7 (1,3 ~ 11,5) | 8,7 (1,8 ~ 14,1) | 11,2 (3,2 ~ 17,7) | 13,4 (3,8 ~ 20,4) | ||
Intermediate climate zone | Pdesignh | kW | 3,3 | 4,7 | 5,8 | 8,2 | 10,5 | |
SCOP | W/W | 4,0 | 4,0 | 4,0 | 4,0 | 4,0 | ||
Energy labelling | A+ | A+ | A+ | A+ | A+ | |||
Tbiv | ºC | -7 | -7 | -7 | -7 | -7 | ||
Tol | ºC | -15 | -15 | -15 | -15 | -15 | ||
Warm climate zone | Pdesignh | kW | 3,6 | 5,0 | 5,6 | 8,6 | 10,5 | |
SCOP | W/W | 5,1 | 5,1 | 5,1 | 5,1 | 5,1 | ||
Energy labelling | A+++ | A+++ | A+++ | A+++ | A+++ | |||
Tbiv | ºC | 2 | 2 | 2 | 2 | 2 | ||
Tol | ºC | -15 | -15 | -15 | -15 | -15 | ||
Indoor unit | Air flow rate (High / Medium / Low) | m3/h | 680 / 580 / 450 | 1.050 / 900 / 780 | 1.360 / 1.200 / 970 | 1.580 / 1.400 / 1.100 | 1.750 / 1.500 / 1.280 | |
Static pressure | Nominal | Pa | 25 | 25 | 25 | 37 | 37 | |
Configurable (*1) | Pa | 0 ~ 45 | 0 ~ 100 | 0 ~ 100 | 0 ~ 100 | 0 ~ 100 | ||
Sound pressure (High / Medium / Low) | dB(A) | 42 / 38 / 35 | 44 / 40 / 37 | 46 / 42 / 38 | 50 / 48 / 44 | 48 / 45 / 40 | ||
Sound power (High) | dB(A) | 54 | 58 | 62 | 65 | 58 | ||
Drain connection | mm | 25 | 25 | 25 | 25 | 25 | ||
Drain pump height (2*) | mm | 750 | 750 | 750 | 750 | 750 | ||
Fresh air intake (3*) | mm | 90 | 90 | 90 | 125 | 125 | ||
Power supply | V-Hz-F | ------ | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | ||
Inner power cable | mm2 | ------ | 2 x 1,5 + T | 2 x 1,5 + T | 2 x 1,5 + T | 2 x 1,5 + T | ||
Wall-mounted wire control | KJR-120G | KJR-120G | KJR-120G | KJR-120G | KJR-120G | |||
Dimensions (Width x Height x Depth) | mm | 700 x 210 x 635 | 920 x 270 x 635 | 920 x 270 x 635 | 1140 x 270 x 775 | 1200 x 300 x 865 | ||
Weight | kg | 18,4 | 26,9 | 28 | 35 | 45 | ||
Outdoor unit | Air flow (High) | m3/h | 2000 | 2100 | 2700 | 4.300 | 4.300 | |
Sound pressure (High) | dB(A) | 57 | 56,5 | 60,5 | 59,5 | 61 | ||
Sound power (High) | dB(A) | 60 | 64 | 65 | 66 | 66 | ||
Compressor (Brand / Model) | GMCC / ASM98D32UFZ | GMCC / ASM135D23UFZ | GMCC / ATF235D22UMT | GMCC / ATF235D22UMT | GMCC / ATF310D43UMT | |||
Power supply | V-Hz-F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | ||
Outdoor power cable | mm2 | 2 x 2,5 + T | 2 x 2,5 + T | 2 x 2,5 + T | 2 x 4 + T | 2 x 4 + T | ||
Dimensions (Width x Height x Depth) | mm | 800 x 554 x 333 | 800 x 554 x 333 | 845 x 702 x 363 | 946 x 810 x 410 | 946 x 810 x 410 | ||
Weight | kg | 34,5 | 35,5 | 49 | 62,9 | 67,2 | ||
Whole set | Communication cable | mm2 | 4 x 1,5 | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | |
Refrigerant | Type | R410A | R410A | R410A | R410A | R410A | ||
Load | Kg | 1,38 | 1,78 | 1,95 | 2,8 | 3,2 | ||
Preloading until | m | 5 | 5 | 5 | 5 | 5 | ||
Additional load (from 5 m) | g/m | 15 | 15 | 30 | 30 | 30 | ||
Design pressure (High / Low) | MPa | 4,2 / 1,5 | 4,2 / 1,5 | 4,2 / 1,5 | 4,2 / 1,5 | 4,2 / 1,5 | ||
Connection pipes | Liquid / Gas | mm (inch) | 6,35 / 9,52 (1/4" / 3/8") | 6,35 / 12,7 (1/4" / 1/2") | 9,52 / 15,9 (3/8" / 5/8") | 9,52 / 15,9 (3/8" / 5/8") | 9,52 / 15,9 (3/8" / 5/8") | |
Max. Length (*4) | m | 25 | 30 | 50 | 50 | 65 | ||
Max. slope | m | 10 | 20 | 25 | 25 | 30 | ||
Operation temperature | Indoor (Cool. / Heat.) | ºC | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | |
Outdoor (Cool. / Heat.) | ºC | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 |
Model | MUCR-42-H6 | MUCR-48-H6 | MUCR-48-H6T | MUCR-60-H6T | |||
---|---|---|---|---|---|---|---|
Code | CL20255 | CL20256 | CL20257 | CL20258 | |||
Cooling | Nominal capacity (min. - max.) | kW | 12,02 (3,22 ~ 13,19) | 14,07 (4,10 ~ 16,41) | 14,07 (4,10 ~ 16,41) | 15,82 (4,98 ~ 18,11) | |
Nominal consumption (min. - max.) | W | 4.090 (1.070 ~ 5.070) | 5.115 (1.370 ~ 6.310) | 5.115 (1.370 ~ 6.310) | 5.255 (1.660 ~ 6.965) | ||
Nominal current (min - máx) | A | 17,8 (4,6 ~ 22,0) | 23,4 (5,9 ~ 27,4) | 8,8 (2,4 ~ 10,9) | 9,1 (2,9 ~ 12,0) | ||
Pdesignc | kW | 12,1 | 14,0 | 14,0 | 16,0 | ||
SEER | W/W | 5,6 | 6,3 | 6,1 | 6,1 | ||
Energy labelling | A+ | A++ | A++ | A++ | |||
Calefacción | Nominal capacity (min. - max.) | kW | 13,48 (2,93 ~ 14,65) | 16,12 (4,34 ~ 18,13) | 16,12 (4,34 ~ 18,13) | 18,17 (5,28 ~ 20,51) | |
Nominal consumption (min. - max.) | W | 3.535 (975 ~ 5.230) | 4.355 (1.445 ~ 6.475) | 4.355 (1.445 ~ 6.475) | 5.033 (1.760 ~ 7.320) | ||
Nominal current (min - máx) | A | 15,4 (4,2 ~ 22,7) | 19,9 (6,2 ~ 28,1) | 7,5 (2,5 ~ 11,2) | 8,7 (3,0 ~ 12,6) | ||
Zona climática intermedia | Pdesignh | kW | 11,0 | 12,2 | 12,2 | 12,3 | |
SCOP | W/W | 4,0 | 4,0 | 4,0 | 4,0 | ||
Energy labelling | A+ | A+ | A+ | A+ | |||
Tbiv | ºC | -7 | -7 | -7 | -7 | ||
Tol | ºC | -15 | -15 | -15 | -15 | ||
Intermediate climate zone | Pdesignh | kW | 11,6 | 11,8 | 11,6 | 12,3 | |
SCOP | W/W | 5,1 | 5,1 | 5,1 | 5,1 | ||
Energy labelling | A+++ | A+++ | A+++ | A+++ | |||
Tbiv | ºC | 2 | 2 | 2 | 2 | ||
Tol | ºC | -15 | -15 | -15 | -15 | ||
Indoor unit | Air flow rate (High / Medium / Low) | m3/h | 2.200 / 1.900 / 1.600 | 2.200 / 1.900 / 1.600 | 2.200 / 1.900 / 1.600 | 2.200 / 1.900 / 1.600 | |
Static pressure | Nominal | Pa | 50 | 50 | 50 | 50 | |
Configurable (*1) | Pa | 0 ~ 100 | 0 ~ 100 | 0 ~ 100 | 0 ~ 100 | ||
Sound pressure (High / Medium / Low) | dB(A) | 50 / 47 / 44 | 51 / 48 / 45 | 50 / 47 / 44 | 50 / 47 / 45 | ||
Sound power (High) | dB(A) | 68 | 68 | 68 | 69 | ||
Drain connection | mm | 25 | 25 | 25 | 25 | ||
Drain pump height (2*) | mm | 750 | 750 | 750 | 750 | ||
Fresh air intake (3*) | mm | 125 | 125 | 125 | 125 | ||
Power supply | V-Hz-F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | ||
Inner power cable | mm2 | 2 x 1,5 + T | 2 x 1,5 + T | 2 x 1,5 + T | 2 x 1,5 + T | ||
Wall-mounted wire control | KJR-120G | KJR-120G | KJR-120G | KJR-120G | |||
Dimensions (Width x Height x Depth) | mm | 1200 x 300 x 865 | 1200 x 300 x 865 | 1200 x 300 x 865 | 1200 x 300 x 865 | ||
Weight | kg | 43,4 | 43,2 | 43,2 | 43,1 | ||
Outdoor unit | Air flow (High) | m3/h | 4.300 | 6.800 | 6.800 | 7.200 | |
Sound pressure (High) | dB(A) | 62,5 | 65 | 65 | 62,5 | ||
Sound power (High) | dB(A) | 71 | 72 | 72 | 75 | ||
Compressor (Brand / Model) | GMCC / ATF310D43UMT | GMCC / ATQ420D1UMU | GMCC / ATQ420D1UMU | GMCC / ATQ420D1UMU | |||
Power supply | V-Hz-F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 380-415V~ 50Hz, 3F | 380-415V~ 50Hz, 3F | ||
Outdoor power cable | mm2 | 2 x 6 + T | 2 x 6 + T | 4 x 2,5 + T | 4 x 2,5 + T | ||
Dimensions (Width x Height x Depth) | mm | 946 x 810 x 410 | 952 x 1333 x 415 | 952 x 1333 x 415 | 952 x 1333 x 415 | ||
Weight | kg | 70,5 | 95,1 | 108,1 | 112,8 | ||
Whole set | Communication cable | mm2 | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | |
Refrigerant | Type | R410A | R410A | R410A | R410A | ||
Load | Kg | 3,65 | 4 | 4 | 4,3 | ||
Preloading until | m | 5 | 5 | 5 | 5 | ||
Additional load (from 5 m) | g/m | 30 | 30 | 30 | 30 | ||
Design pressure (High / Low) | MPa | 4,2 / 1,5 | 4,2 / 1,5 | 4,2 / 1,5 | 4,2 / 1,5 | ||
Connection pipes | Liquid / Gas | mm (inch) | 9,52 / 15,9 (3/8" / 5/8") | 9,52 / 15,9 (3/8" / 5/8") | 9,52 / 15,9 (3/8" / 5/8") | 9,52 / 15,9 (3/8" / 5/8") | |
Max. Length (*4) | m | 65 | 65 | 65 | 65 | ||
Max. slope | m | 30 | 30 | 30 | 30 | ||
Operation temperature | Indoor (Cool. / Heat.) | ºC | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | 17 ~ 32 / 0 ~ 30 | |
Outdoor (Cool. / Heat.) | ºC | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 | -15 ~ 50 / -15 ~ 24 |
Notes:
(1*) Configurable static pressure via Micro-switch ENC2 on the indoor PCB
(2*) Pump height measured from the unit shaft. The elbow is set horizontally at 200 mm maximum.
(3*) Inner diameter
(4*) Pipes minimum length of 2 m
* The above design and specifications are subject to change of product improvement without prior notice.
** The values of noise level match with values obtained in the anechoic chamber.
MODEL | PIPES | ELECTRICAL CONNECTIONS | |||||||
---|---|---|---|---|---|---|---|---|---|
Gas | Liquid | Max. Length (B) | Max. slope (A) | Preloading until | Additional charge | Supply | Com. (C) | ||
Indoor (E) | Outdoor (D) | ||||||||
MUCR-12-H6 | 3/8" | 1/4" | 25 m | 10 m | 5 m | 15 gr/m | (Only Outdoor) | 2 x 2.5 + T | 4 x 1,5 |
MUCR-18-H6 | 1/2" | 1/4" | 30 m | 20 m | 5 m | 15 gr/m | 2 x 1.5 + T | 2 x 2,5 + T | 2 x 0,75 (Apant.) |
MUCR-24-H6 | 5/8" | 3/8" | 50 m | 25 m | 5 m | 30 gr/m | 2 x 1.5 + T | 2 x 2,5 + T | 2 x 0,75 (Apant.) |
MUCR-30-H6 | 5/8" | 3/8" | 50 m | 25 m | 5 m | 30 gr/m | 2 x 1.5 + T | 2 x 4 + T | 2 x 0,75 (Apant.) |
MUCR-36-H6 | 5/8" | 3/8" | 65 m | 30 m | 5 m | 30 gr/m | 2 x 1.5 + T | 2 x 4 + T | 2 x 0,75 (Apant.) |
MUCR-42-H6 | 5/8" | 3/8" | 65 m | 30 m | 5 m | 30 gr/m | 2 x 1.5 + T | 2 x 6 + T | 2 x 0,75 (Apant.) |
MUCR-48-H6 | 5/8" | 3/8" | 65 m | 30 m | 5 m | 30 gr/m | 2 x 1.5 + T | 2 x 6 + T | 2 x 0,75 (Apant.) |
MUCR-48-H6T | 5/8" | 3/8" | 65 m | 30 m | 5 m | 30 gr/m | 2 x 1.5 + T | 4 x 2.5 + T | 2 x 0,75 (Apant.) |
MUCR-60-H6T | 5/8" | 3/8" | 65 m | 30 m | 5 m | 30 gr/m | 2 x 1.5 + T | 4 x 2.5 + T | 2 x 0,75 (Apant.) |
Model | MUCR-18X2-H6 | MUCR-24X2-H6 | MUCR-24X2-H6T | MUCR-30X2-H6T | ||
---|---|---|---|---|---|---|
Code | CL20928 | CL20929 | CL20930 | CL20931 | ||
Total capacity | Cooling / Heating | kW | 10,55 / 11,13 | 14,07 / 16,12 | 14,07 / 16,12 | 15,82 / 18,17 |
Indoor units | Model | MUCR-18-H6 | MUCR-24-H6 | MUCR-24-H6 | MUCR-30-H6 | |
Code | UI20251 | UI20252 | UI20252 | UI20253 | ||
Amount | 2 | 2 | 2 | 2 | ||
Individual capacity (Cool.) / Heat.) | kW | 5,28 / 5,57 | 7,03 / 8,06 | 7,03 / 8,06 | 7,91 / 9,08 | |
Power supply | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | ||
Outdoor Unit | Model | MUCR-36-H6 | MUCR-48-H6 | MUCR-48-H6T | MUCR-60-H6T | |
Code | UE20254 | UE20256 | UE20257 | UE20258 | ||
Amount | 1 | 1 | 1 | 1 | ||
Power supply | 220-240V~ 50Hz, 1F | 220-240V~ 50Hz, 1F | 380-415V~ 50Hz, 3F | 380-415V~ 50Hz, 3F | ||
Branch pipe | Model | FQZHN-01D | FQZHN-01D | FQZHN-01D | FQZHN-01D | |
Code | TF03611 | TF03611 | TF03611 | TF03611 | ||
Amount | 1 | 1 | 1 | 1 | ||
Connection pipes | Out. unit to distributor (Liq./Gas) | inch | 3/8" - 5/8" | 3/8" - 5/8" | 3/8" - 5/8" | 3/8" - 5/8" |
Ind. unit to distributor (Liq./Gas) | inch | 1/4" - 1/2" | 3/8" - 5/8" | 3/8" - 5/8" | 3/8" - 5/8" | |
Communication cable (*1) | mm2 | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) | 2 x 0,75 (shielded) |
Note:
(*1) The cable has to be wired up from t h e outdoor unit to the Master indoor unit, then from the Master to the Slave indoor unit.
The indoor units have to be set up as Master and Slave. They can be set up using the Micro-switch on the indoor PCB or using the remote control RG57.
IMPORTANT : In Twin systems, the indoor units ALWAYS work together and uniformly. THEY CAN NOT WORK INDEPENDENTLY