MUPR-H7 Series

Domestic range

CL20015_018

Wall split MUPR-H7 Series

(R32 refrigerant)

SAVES INSTALLATION TIME

Easily dismanteled

Easy access to PCB, detachable fan, movable housing.

Save 30 % of maintenance time.

More space for installation

New bracket, fastener feet, simpler electrical connection.

Save 20 % of installation time.

More accessible filters

Without the need to open the panel, it avoids the dirt to fall down.

Save 5% of cleaning time.

Wide range of connectivity

Possibility of connecting different control devices, among them also a WlFl module.

Turn on your new air conditioner Mundoclima from anywhere you are.

Characteristics

  • More ecological thanks to R32 refrigerant
  • Follow Me Function
  • Automatic restart
  • Emergency operation
  • Cold air protection
  • Turbo operation
  • Low sound level
  • Temperature compensation
  • Different speeds of the external fan
  • Less screws
  • Cooling in low temperatures
  • Standby Function (only 1W in standby)
  • Refrigerant leak detection
  • Setpoint temperatures range adjustment
  • Multi-speed indoor fan
  • Feet in U form
  • More silent outdoor unit
  • Sleep Mode
  • 8ºC Heating
  • WIFI module (optional)

     Technical documentation

Data SheetES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
Owner's and installation manualES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
Service manualEN 18X18
Function selection manualES 18X18EN 18X18FR 18X18
Wifi Module ManualES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
Multi function module manualES 18X18EN 18X18
Wired control KJR-120C manualES 18X18EN 18X18FR 18X18DE 18X18
Energy LabelsES 18X18EN 18X18FR 18X18DE 18X18
Tables Seasonal Performance
EC Declaration of conformityES 18X18EN 18X18FR 18X18DE 18X18PT 18X18

E ENERGETICO 4_0

Follow Me Function

The wireless remote control incorporates a temperature sensor.

Automatic restart

Recovery of the adjustments before the electrical cut.

Emergency operation

Possibility of unit operation with the manual button in case of activation of some alarms.

Cold air protection

In heating, the initial fan speed is adjusted in accordance with the coil temperature.

Turbo operation

Maximum cooling/heating time reduction.

Less screws

Not only the indoor unit but also the outdoor unit have less screws, so the disassembly is going to be easier.

Low sound level

Thanks to the Silence mode and its new design, the sound level decrease up to a minimum of 22 dB (MUPR-09-H7). In outdoor unit design optimized of the air exit grill with decrease of the noise up to 3.3 dB (A) in comparison with previous models.

Setpoint temperatures range adjustment

The new remote control is able to adjust: Minimum cooling from 17º C up to 24º C. Maximum heating from 30º C up to 25ºC.

Detección de fugas de refrigerante

Refrigerant leak detection

The unit automatically detects the existence of possible leaks of refrigerant in the circuit.

Multi-speed indoor fan

Up to 12 levels of fan speed automatically adjusted if the automatic ventilation is activated.

Auto self cleanning

This function performs a cleaning indoor coil, maintaining the equipment dry and preventing bacteria generated.

8ºC Heating

This function ensures that the room temperature in winter never be less than 8 ° C while we are not at home.

3 modos nocturnos

Sleep mode

This feature allows the unit to automatically increase or decrease cooling temperature heating temperature 1 ° C per hour for the first 2 hours, then keep constant in the next 5 hours and finally shut down. This feature saves energy and provides comfort during the night.

icona-refrigeracion-temperaturas-bajas

Cooling in low temperatures

Operation in cooling up to -15º C outdoor.

icona-compensacion-temperatura

Temperature compensation

The new remote control allows to adjust compensation temperature for the heating mode.

Multi-speed outdoor fan

Precise adjustment of the fan speed thanks to the DC motor.

Función Stanby (sólo 1w)

Standby Function (only 1W in standby)

The outdoor unit is automatically disconnected from the supply when the unit is in standby, in that way the consumption in standby modus is only 1W.

Wide working temperature range

Cooling operation until 50º C and in heating until -15º C.

Filtro Catalizador Frío

Feet in U form

Thanks to the new back feet in the outdoor unit installation is easier (iexcept MUPR-18-H7).

WIFI module  (Optional)

Possibility to connect a WIFI module to control your computer from anywhere with SmartPhone.

TECHNICAL SPECIFICATIONS

ModelMUPR-09-H7MUPR-12-H7MUPR-18-H7MUPR-24-H7
CodeCL20035CL20036CL20037CL20038
CoolingRated capacity (min. ~ max.)kW2,63 (1,20 - 3,42)3,51 (1,40 - 4,57)5,27 (1,96 - 6,21)7,32 (3,04 - 8,44)
Rated consumption (min. - max.)kW0,77 (0,10 - 1,32)1,25 (0,11 - 1,74)1,50 (0,15 - 2,22)2,26 (0,23 - 3,01)
PdesignckW2,63,55,37,3
SEERW/W6,86,57,16,9
Energy labellingA++A++A++A++
HeatingRated capacity (min. ~ max.)kW2,93 (0,82 - 3,86)4,10 (0,87 - 5,12)5,56 (1,28 - 6,97)7,61 (2,08 - 9,43)
Rated consumption (min. - max.)kW0,78 (0,14 - 1,38)1,17 (0,15 - 1,83)1,39 (0,22 - 2,33)2,11 (0,33 - 3,15)
Intermediate climate zonePdesignhkW2,42,54,25,6
SCOPW/W4444
Energy labellingA+A+A+A+
TbivºC-7-7-6-7
Warm climate zonePdesignhkW33,24,57
SCOPW/W5,15,25,15,1
Energy labellingA+++A+++A+++A+++
TbivºC2222
Tol (Limited operating temperature)ºC-15-15-15-15
Power supplyV-Hz-F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F
Max. consumptionkW2,0752,22,553,6
Max. currentA9,51011,516
Indoor unitAir flow rate (High /Medium /Low)m3/h486 / 433 / 329550 / 490 / 360810 / 720 / 5501050 / 970 / 650
Sound pressure (High / Medium/ Low / Silence)dB(A)41 / 34 / 29 / 2241 / 37 / 30 / 2345 / 41 / 33 / 2446 / 44 / 35 / 27
Sound power (High)dB(A)53545759
Dimensions (W x H x D)mm717 x 302 x 193805 x 302 x 193964 x 325 x 2221106 x 342 x 232
WeightKg7,58,210,814,3
Outdoor unitAir flow rate (max.)m3/h2000200021002700
Sound pressure (High)dB(A)55555759
Sound power (High)dB(A)58606065
Dimensions (W x H x D)mm770 x 555 x 300770 x 555 x 300800 x 554 x 333845 x 702 x 363
WeightKg26,426,53748
RefrigerantTypeR32R32R32R32
LoadKg0,70,81,251,6
Preloading untilm5555
Additional load (from 5 m)g/m12121224
Connection pipesLiquidmm(inch)6,35 (1/4")6,35 (1/4")6,35 (1/4")9,52 (3/8")
Gasmm(inch)9,52 (3/8")9,52 (3/8")12,7 (1/2")15,9 (5/8")
Max. Lengthm25253050
Max. Drop Heightm10102025
Electrical power wiringSupply (outdoor unit)mm22 x 2,5 + T2 x 2,5 + T2 x 2,5 + T2 x 4 + T
Interconnectionmm24 x 2,5 + T4 x 2,5 + T4 x 2,5 + T4 x 4 + T
Wireless remote controlRG57RG57RG57RG57
Operating temperatureIndoor (Cooling / Heating)ºC17 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 30
Outdoor (Cooling / Heating)ºC-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30
Note:
1. Data and specifications are subject to changes without previous notice.
2. The values of noise level match with values obtained in the anechoic chamber.

PRE-INSTALLATION REQUIREMENTS

 

MODELPIPESELECTRICAL CONECTIONS
GasLiquidMax. Lengh (B)Max. Drop Height (A)Preloading untilAdditional chargePower supply (D)Interconnection (C)
MUPR-09-H73/8"1/4"25 m10 m5 m12 gr/m2 x 2.5 + T 4 x 2.5 + T
MUPR-12-H73/8"1/4"25 m10 m5 m12 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-18-H71/2"1/4"30 m20 m5 m12 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-24-H75/8"3/8"50 m25 m5 m24 gr/m2 x 4 + T4 x 4 + T

TUBERIAS-MUPR-H4_multi

CONEXIONES MUPR-H4

 

 

 

 

 

 

 

 

 

 

OPTIONALS

 

DESCRIPTIONCODE
Wifi moduleCL94382
Wired control KJR-12BCL92905
Multi-Function module, includes:
- Remote signal ON/OFF
CL94383
- Alarm remote signal
- Connection of wired control with week schedule (KJR-120C)
- Connection of centralized CCM
Wired control week schedule KJR-120C*CL94384
Centralized controller*
CCM03/E(M)
CL92911
CCM30/BKE-B
CL92871
Note: