MUPR-H5 Series

Domestic range

CL20736-738

Wall Split MUPR-H5 Series

Hidden LED Display

The light is hidden under the front panel, so the temperature and error codes are displayed in a more elegant way.

Turbo operation

This function increases the heating or cooling to the maximum effect. So the air cools or heats up quickly and the desired temperature is achieved in a short time.

Characteristics

  • Automatic restart
  • Emergency operation
  • Turbo operation
  • Intelligent function anti-cold
  • Refrigerant leak detection
  • Auto cleaning
  • Feeling function
  • Low voltage start
  • Standby function (1W)

     Technical specifications

Data SheetES
Owner's and installation manualESENFRPT
Service manualEN

Automatic restart

If there is a power failure and the unit turns off, once power supply is restored, the unit restarts automatically with the last selected settings.

Emergency operation

If an error occurs in the temperature sensor, the air conditioner will display an error code and it will turn off immediately.

Intelligent anti-cold function

When cooling mode is on, the fan speed increases automatically from the predetermined lowest level, according to the heating of the evaporator. So the initial cold flow exit is avoided which is not pleasant for the user.

Turbo operation

This function increases the heating or cooling to the maximum effect. In this way the atmosphere cools or heats up quickly and the desired temperature is achieved in a short period of time.

Detección de fugas de refrigerante

Refrigerant leak detection

With this new technology, an alarm sounds from the indoor unit if a coolant leak on the outdoor unit is detected.

Auto cleaning

This function performs a indoor coil cleaning, keeping the equipment dry and preventing bacteria to be generated.

Start at low voltage

The team can start and run normally until a supply voltage of 165 V.

Función Stanby (sólo 1w)

Standby function (only 1 W)

ON/OFF intelligent technology allows energy saving in Standby mode. In this way the energy consumption can be reduced from 4-5 W to 1 W, resulting in an energy saving of 80%.

Feeling function

The wireless remote control incorporates a temperature sensor. The unit automatically selects the operating mode in order to achieve greater control and comfort in temperature.

TECHNICAL SPECIFICATIONS

ModelMUPR-09-H5MUPR-12-H5MUPR-18-H5
CodeCL 20 736CL 20 737CL 20 738
CoolingCapacitykW2,53,55,2
Kcal/h2.1503.0104.472
Power input (max.)W778 (1.500)1,080 (1.800)1,700 (2.250)
HeatingCapacitykW2,63,65,3
Kcal/h2.2363.0964.558
Power input (max.)W715 (1.500)984 (1.800)2,100 (2.250)
SEERW/W5,65,65,6
Energy efficiency of cooling typesA+A+A+
SCOPW/W3,83,83,8
Energy efficiency of heating typesAAA
Min. working temperatureºC-10-10-10
Indoor air flow (High)m3/h500560920
Indoor sound pressure (High)dB(A)424247
Outdoor air flow (High)m3/h1.6901.9502.500
Outdoor sound pressure (High)dB(A)545557
Net dimensions (mm)Indoor (W x D x H)mm802 x 190 x 265802 x 190 x 265940 x 220 x 300
Outdoor (W x D x H)mm720 x 260 x 540760 x 260 x 540800 x 300 x 690
Net weightIndoorkg7712
Outdoorkg262746
Connection pipesLiquidinches1/4" 1/4" 1/4"
Gasinches3/8" 1/2" 5/8"
Warning:
1. Data and specifications are subject to changes without previous notice.
2. The values of noise level match with values obtained in the anechoic chamber.

PRE-INSTALLATION REQUIREMENTS

 

MODELPIPESELECTRICAL CONNECTIONS
GasLiquidMax. Length (B)Max. slope (A)Preloading until:Additional chargeSupply (D)Interconection (C)
MUPR-09-H53/8"1/4"15 m5 m5 m20 gr/m2 x 2.5 + T3 x 2.5 + T
MUPR-12-H51/2"1/4"15 m5 m5 m20 gr/m2 x 2.5 + T3 x 2.5 + T
MUPR-18-H55/8"1/4"15 m5 m5 m30 gr/m2 x 4 + T3 x 4 + T

TUBERIAS-MUPR-H4_multi

CONEXIONES MUPR-H5