Wall split MUPR-H6 Series

SAVES INSTALLATION TIME

Easily dismanteled

Easy access to PCB, detachable fan, movable housing.

Save 30 % of maintenance time.

More space for installation

New bracket, fastener feet, simpler electrical connection.

Save 20 % of installation time.

More accessible filters

Without the need to open the panel, it avoids the dirt to fall down.

Save 5% of cleaning time.

Wide range of connectivity

Possibility of connecting different control devices, among them also a WlFl module.

Turn on your new air conditioner Mundoclima from anywhere you are.

Characteristics

  • Follow Me Function
  • Automatic restart
  • Emergency operation
  • Cold air protection
  • Turbo operation
  • Low sound level
  • Temperature compensation
  • Different speeds of the external fan
  • Less screws
  • Cooling in low temperatures
  • Standby Function (only 1W in standby)
  • Refrigerant leak detection
  • Setpoint temperatures range adjustment
  • Multi-speed indoor fan
  • Feet in U form
  • More silent outdoor unit
  • Sleep Mode
  • 8ºC Heating
  • WIFI module (optional)

     Technical documentation

Data SheetES 18X18EN 18X18FR 18X18DE 18X18
Owner's and installation manualES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
Service manualEN 18X18
Function selection manualES 18X18EN 18X18FR 18X18
Wifi Module ManualES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
Multi function module manualES 18X18EN 18X18
Wired control KJR-120C manualES 18X18EN 18X18FR 18X18DE 18X18
Energy LabelsES 18X18EN 18X18FR 18X18DE 18X18
Tables Seasonal PerformanceEN 18X18

E ENERGETICO 4_0

Follow Me Function

The wireless remote control incorporates a temperature sensor.

Automatic restart

Recovery of the adjustments before the electrical cut.

Emergency operation

Possibility of unit operation with the manual button in case of activation of some alarms.

Cold air protection

In heating, the initial fan speed is adjusted in accordance with the coil temperature.

Turbo operation

Maximum cooling/heating time reduction.

Less screws

Not only the indoor unit but also the outdoor unit have less screws, so the disassembly is going to be easier.

Low sound level

Thanks to the Silence mode and its new design, the sound level decrease up to a minimum of 20 dB (MUPR-09-H6). In outdoor unit design optimized of the air exit grill with decrease of the noise up to 3.3 dB (A) in comparison with previous models.

Setpoint temperatures range adjustment

The new remote control is able to adjust: Minimum cooling from 17º C up to 24º C. Maximum heating from 30º C up to 25ºC.

Detección de fugas de refrigerante

Refrigerant leak detection

The unit automatically detects the existence of possible leaks of refrigerant in the circuit.

Multi-speed indoor fan

Up to 12 levels of fan speed automatically adjusted if the automatic ventilation is activated.

Auto self cleanning

This function performs a cleaning indoor coil, maintaining the equipment dry and preventing bacteria generated.

8ºC Heating

This function ensures that the room temperature in winter never be less than 8 ° C while we are not at home.

3 modos nocturnos

Sleep mode

This feature allows the unit to automatically increase or decrease cooling temperature heating temperature 1 ° C per hour for the first 2 hours, then keep constant in the next 5 hours and finally shut down. This feature saves energy and provides comfort during the night.

icona-refrigeracion-temperaturas-bajas

Cooling in low temperatures

Operation in cooling up to -15º C outdoor.

icona-compensacion-temperatura

Temperature compensation

The new remote control allows to adjust compensation temperature for the heating mode.

Multi-speed outdoor fan

Precise adjustment of the fan speed thanks to the DC motor.

Función Stanby (sólo 1w)

Standby Function (only 1W in standby)

The outdoor unit is automatically disconnected from the supply when the unit is in standby, in that way the consumption in standby modus is only 1W.

Wide working temperature range

Cooling operation until 50º C and in heating until -15º C.

Filtro Catalizador Frío

Feet in U form

Thanks to the new back feet in the outdoor unit installation is easier (in models MUPR-09/24-H6).

WIFI module  (Optional)

Possibility to connect a WIFI module to control your computer from anywhere with SmartPhone.

TECHNICAL SPECIFICATIONS

ModelMUPR-09-H6MUPR-12-H6MUPR-18-H6MUPR-24-H6
CodeCL20015CL20016CL20017CL20018
Cooling
Rated capacity (min ~ max)
kW2,63 (1,17 ~ 3,31)3,51 (1,26 ~ 4,45)5,27 (1,90 ~ 6,12)7,03 (2,66 ~ 7,88)
Rated consumption (min ~ max)
kW0,816 (0,1 ~ 1,27)1,153 (0,11 ~ 1,72)1,633 (0,15 ~ 2,35)2,306 (0,23 ~ 3,03)
Pdesignc
kW2,63,55,37,0
SEER
W/W6,86,76,86,4
Energy efficiency class
A++A++A++A++
Heating
Rated capacity (min ~ max)
kW2,93 (0,82 ~ 3,72)3,81 (1,06 ~ 4,86)5,56 (1,42 ~ 6,74)7,62 (2,08 ~ 9,14)
Rated consumption (min ~ max)
kW0,811 (0,14 ~ 1,33)1,055 (0,17 ~ 1,74)1,5 (0,23 ~ 2,4)2,302 (0,31 ~ 3,27)
Intermediate climate zone
Pdesignh
kW2,42,64,45,6
SCOP
W/W4,14,24,24,0
Energy efficiency class
A+A+A+A+
Tbiv
ºC-7-7-6-7
Warm climate zone
Pdesignh
kW3,03,04,77,2
SCOP
W/W5,105,205,405,20
Energy efficiency class
A+++A+++A+++A+++
Tbiv
ºC2254
Tol ºC-15-15-15-15
Power SupplyV-Hz-F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F220-240V~ 50Hz, 1F
Max. consumptionkW2,0752,22,553,7
Max. currentA9,51011,517
Indoor unit
Air flow rate (H/M/L)
m3/h472 / 360 / 254562 / 497 / 224870 / 730 / 5001176 / 921 / 446
Sound pressure (H/M/L/Silence)
dB(A)40 / 35 / 28 / 2041 / 40 / 33 / 2245 / 43 / 34 / 2447 / 45 / 35 / 28
Sound power (H)
dB(A)53525860
Dimensions (W x H x D)
mm717 x 302 x 193805 x 302 x 193964 x 325 x 2221106 x 342 x 232
Weight
Kg7,07,710,113,2
Outdoor unit
Air flow rate (H)
m3/h1900200021002700
Sound pressure (H)
dB(A)55565861
Sound power (H)
dB(A)58596365
Dimensions (W x H x D)
mm770 x 555 x 300800 x 554 x 333800 x 554 x 333845 x 702 x 363
Weight
Kg26,629,137,848,4
Refrigerant
Type
R410AR410AR410AR410A
Charge
Kg0,80,951,482,0
Precharge until
m5555
Additional charge (from 5m)
g/m15151530
Conection pipes
Liquid
mm(inch)6,35 (1/4")6,35 (1/4")6,35 (1/4")9,52 (3/8")
Gas
mm(inch)9,52 (3/8")9,52 (3/8")12,7 (1/2")15,9 (5/8")
Max. Lenght
m25253050
Max. Drop height
m10102025
Electrical wiring
Power Supply (outdoor unit)
mm22 x 2,5 + T2 x 2,5 + T2 x 2,5 + T2 x 4 + T
Interconnection
mm24 x 2,5 + T4 x 2,5 + T4 x 2,5 + T4 x 4 + T
Remote controlRG57RG57RG57RG57
Operation temperature
Indoor (Cooling / Heating)
ºC17 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 3017 ~ 32 / 0 ~ 30
Outdoor (Cooling / Heating)
ºC-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30-15 ~ 50 / -15 ~ 30
Note:
1. Data and specifications are subject to changes without previous notice.
2. The values of noise level match with values obtained in the anechoic chamber.

PRE-INSTALLATION REQUIREMENTS

 

MODELPIPESELECTRICAL CONECTIONS
GasLiquidMax. Lengh (B)Max. Drop Height (A)Preloading untilAdditional chargePower supply (D)Interconnection (C)
MUPR-09-H63/8"1/4"25 m10 m5 m15 gr/m2 x 2.5 + T 4 x 2.5 + T
MUPR-12-H63/8"1/4"25 m10 m5 m15 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-18-H61/2"1/4"30 m20 m5 m15 gr/m2 x 2.5 + T4 x 2.5 + T
MUPR-24-H65/8"3/8"50 m25 m5 m30 gr/m2 x 4 + T4 x 4 + T

TUBERIAS-MUPR-H4_multi

CONEXIONES MUPR-H4

 

 

 

 

 

 

 

 

 

 

OPTIONALS

 

DESCRIPTIONCODE
Wifi moduleCL94382
Wired control KJR-12BCL92905
Multi-Function module, includes:
- Remote signal ON/OFF
CL94383
- Alarm remote signal
- Connection of wired control with week schedule (KJR-120C)
- Connection of centralized CCM
Wired control week schedule KJR-120C*CL94384
Centralized controller*
CCM03/E(M)
CL92911
CCM30/BKE-B
CL92871
Note:
* For connection it is necessary the Multi-function Module (CL94383)