MUNDOCLIMA Aerotherm V2

Industrial range

SO30140_153

Heat pump for hot water production SHW, MUNDOCLIMA Aerotherm Series for heating and cooling

MUNDOCLIMA Aerotherm is an energy solution, for home comfort that uses air as its main energy source. It gives a flexible and economic alternative to boilers. This equipment also allows to enjoy air conditioning in the house.

High performance with a COP of up to 4.45

With a COP up to 4.45 MUNDOCLIMA Aerotherm supplies more heat with less energy consumption.

SHW production, heating and cooling

The heat pump MUNDOCLIMA Aerotherm not only allows use as heating but also allows the supply of sanitary hot water (SHW) and on the other hand it can also provide cooling (air conditioning), when combined with fan coils or other system.

Split system with refrigerant R410a

The Aerotherm system consists of an outdoor and an indoor unit, these are joined by cooling gas R410a refrigerant pipe. The maximum length of pipe between the outdoor and indoor unit is 30 m.

Indoor unit with hydraulic module

The indoor unit incorporates the necessary hydraulic components in each installation, such as circulation pump, flow switch, expansion tank, tank with electric heaters, plate heat exchanger and water pressure gauge.

Intelligent control panel

The indoor unit also incorporates an intelligent control panel, this allows to adjust all operating parameters of the system, simple and easy to understand. There is also the possibility of installing the control panel in the house separately from the indoor unit.

Built-in room temperature sensor

With the system an ambient temperature sensor is incorporated to control the temperature of the room only by the machine’s control panel without placing an external thermostat.

DC Inverter fan motor and compressor

All outdoor units incorporate a DC Inverter fan motor and a compressor, in this way performance of the system is improved in middle frequencies and it ensure a more sensitive and effective control.

Characteristics

  • High performance with a COP up to 4.45
  • DHW production, heating and cooling
  • Divided system with refrigerant R410a
  • Indoor unit with hydraulic module
  • Intelligent control panel
  • Room temperature sensor built-in
  • DC Inverter compressor and fans
  • Best value for money in the market

     Technical documentation

Data SheetES
Technical brochureES
Owner's and Installation manualESEN
Owner's manual Control panelESEN
Service manualESEN
Performance tableES

TECHNICAL SPECIFICATIONS

INDOOR UNIT:

ModelAEROTHERM 8 KWAEROTHERM 12 KWAEROTHERM 16 KWAEROTHERM 16 KW (400V)
CodeSO30141SO30145SO30149SO30153
Voltage rating230V-1-50Hz230V-1-50Hz230V-1-50Hz400V-3-50Hz
Rated power6.200 W (plus resistance)
Water temp.Heating (Fan coil)25 - 55ºC25 - 55ºC25 - 55ºC25 - 55ºC
Heating (Floor heating)25 - 45ºC25 - 45ºC25 - 45ºC25 - 45ºC
Cooling (Fan coil)7 - 25ºC7 - 25ºC7 - 25ºC7 - 25ºC
Cooling (Floor cold)18 - 25ºC18 - 25ºC18 - 25ºC18 - 25ºC
Rest. support3 + 3 kW3 + 3 kW3 + 3 kW6 kW
Dimensions900 x 500 x 324 mm
Net weight57 kg57 kg57 kg60 kg

OUTDOOR UNIT:

ModelAEROTHERM 8 KWAEROTHERM 12 KWAEROTHERM 16 KWAEROTHERM 16 KW (400V)
CodeSO30140SO30144SO30148SO30152
Voltage rating230V-1-50Hz230V-1-50Hz230V-1-50Hz400V-3-50Hz
Capacity (1)HeatingkW8,512,515,515,5
CoolingkW8,512,514,515
Consumption (1)HeatingkW2,052,813,783,78
CoolingkW2,543,574,534,11
COP/EER (1)W/W4,1 / 3,354,45 / 3,54,1 / 3,24,1 / 3,65
Capacity (2)HeatingkW7,5111414
CoolingkW6,29,510,511
Consumption (2)HeatingkW2,53,1444,12
CoolingkW2,383,393,963,73
COP/EER (2)W/W3 / 2,613.5 / 2,83.5 / 2,653.4 / 2,95
CompressorBLDC Inverter
Refrigerant loadkg2,13,23,23,4
Refrigerant connectionsGasinch5/8"5/8"5/8"5/8"
Liquidinch3/8"3/8"3/8"3/8"
Temp. SHWºC40 - 80 (connection 1" M)
Sound levelHeatingdB(A)55575858
CoolingdB(A)54555757
DimensionsWxDxHmm980 x 360 x 790900 x 412 x 1345900 x 412 x 1345900 x 412 x 1345
Net weightkg75106106107

Notes:

(1) Capacity and powers based on the following conditions:

Cooling: Internal water temp.: 23ºC/18ºC. Temp. Outdoor: 35ºC DB/24ºC WB.

Heating: Internal water temp.: 30/35ºC. Temp. Ext. Air: 7ºC DB/6ºC WB.

(2) Capacity and powers based on the following conditions:

Cooling: Indoor water temp.: 12ºC/7ºC. Temp. Outdoor: 35ºC DB/24ºC WB.

Heating: Indoor water temp.: 40/45ºC. Temp. Ext. Air: 7ºC DB/6ºC WB.