Centrifugal Variable Flow "Hiden"

industrial Range

VRF Outdoor Units

The new variable refrigerant flow (VRF) system that comes with the 90Pa pressure centrifugal exterior unit, provides an ideal solution for all exterior unit installations that can’t be performed outside.

Features

  • Centrifugal outdoor unit
  • Less than 3,600 m³/h
  • Possibility to rotate the air outlet side
  • Connection of up to 7 indoor units
  • DC Inverter Technology
  • Wide operating range
  • Up to 100 m of piping
  • Automatic addressing

Technical Documentation

Data sheetESENFR 18X18DE 18X18PT 18X18
Use and installation manual and information requirements ESENFR 18X18DE 18X18PT 18X18
Technical Manual
Software Selection (Multi Language)EN 18X18

VERSATILITY – Outdoor centrifugal unit

The variable refrigerant flow (VRF) system that comes with the 90 Pa static pressure centrifugal exterior unit, provides an ideal solution for all exterior unit installations that can’t be installed outside.

VERSATILITY – Less than 3,600 m³/h

The 14 kW model expels less than 3,600 m³/h (in quiet mode), thus complying with the autonomous communities regulations that determine this value as the maximum flow permitted to be expelled to the outside environment.

VERSATILITY– Possibility to switch the side of the air outlet

The air outlet can be switched outside (the fan must be rotated).

VERSATILITY– Connection of up to 7 indoor units

Connection from only one indoor unit to a maximum of 7, depending on the capacity of each unit.

HIGH EFFICIENCY – DC Inverter Technology

The compressor and the fan motor are DC Inverter, this way the performance is improved in medium frequencies and it ensures a more sensitive and effective control.

CONFORT – WIDE WORKING TEMPERATURE RANGE

The "HIDEN" series can stably operate in heating mode between -15 ~ 30°C and in cooling between -5 ~ 50°C.

EASIER INSTALLATION – Up to 100 m of piping

  • Total pipe length: 100 m.
  • Pipe length of the furthest indoor unit (equivalent): 60 m (70 m)
  • Length of pipe between the first distributor and the furthest indoor unit: 20 m
  • Height difference between indoor and outdoor units (OU higher): 20 m (30 m)
  • Height difference between indoor units: 8 m

EASIER INSTALLATION – Automatic addressing

By default, the first time the power supply to the entire system is activated, the outdoor unit automatically assigns the address to each indoor unit. The address of each indoor unit can be checked and changed later with the wireless controller.