Mini MVD V4+

Industrial range

CL23269-271

Mini MVD V4+

The Mini MVD V4+ system made of 8 to 45 kW units, allows the connection up to 14 indoor units to the same outdoor unit, with a maximum pipe length up to 250 m.

Characteristics

  • DC Inverter fan motor and compressor
  • Wide range of capabilities
  • Simplified communication connection
  • Auto addressing
  • Maximum length of pipe up to 250 m
  • Wide operating range
  • Total compatibility

     Technical documentation

Data SheetESEN 18X18FR 18X18DE 18X18PT 18X18
Owner's and installation manual (8 to 18kW)ESENFR 18X18DE 18X18PT 18X18
Owner's and installation manual (20 to 26kW)ESENDE 18X18PT 18X18
Owner's and installation manual (40 to 45kW)ES 18X18EN 18X18PT 18X18
Service manual 8 to 26kWES 18X18
Service manual 20 to 45kWEN 18X18
Selection software (mullitilingual)ES 18X18EN 18X18FR 18X18DE 18X18PT 18X18
EC Declaration of conformityES 18X18EN 18X18FR 18X18DE 18X18PT 18X18

DC Inverter fan motor and compressor

All range units incorporate a DC Inverter fan motor and a compressor, in this way performance is improved in middle frequencies and ensure a more sensitive and effective control.

Wide range of capabilities

The new Mini MVD V4+ system provides a wide range of units with capacities from 8 kW to 45 kW which offers the possibility to connect from 4 to 14 indoor units respectively.

Auto addressing

The outdoor unit can assign address to the indoor units automatically.

Wireless controls and wiring KJR-29B, can also configure, query and modify the addresses of the indoor units.

Simplified communication connection

The installation of the communication wiring is simpler because in case you need to install a centralized control is not necessary to wire a second bus for communication between the indoor units and the central control. You can connect the central control directly to the outdoor unit and perform automatic routing, so the control detects all indoor units connected to that outdoor unit, after you can modify the address manually with individual control of each indoor unit.

Maximum length of pipe up to 450 m

The MVD Mini V4+ system supports a maximum pipe length of 120 m (capacities: 20, 22.4 and 26 kW) and 250 (capacities: 40 and 45 kW) and a height difference of 30 m.

Wide range of operation

The Mini MVD V4+ system can operate in extreme temperatures in heating mode up to an outside temperature of -15 °C and in cooling mode up to 48 °C.

Total compatibility

The Mini MVD V4+ system is compatible with all MVD indoor units.

TECHNICAL SPECIFICATIONS

 

ModelMVD-V80W/DN1MVD-V105W/DN1MVD-V120W/DN1MVD-V140W/DN1MVD-V160W/DN1(B)
CodeCL23260CL23261CL23262CL23263CL23264
Power supply1N-, 230V, 50Hz1N-, 230V, 50Hz1N-, 230V, 50Hz1N-, 230V, 50Hz1N-, 230V, 50Hz
Cooling (1)CapacitykW7,2 (1,6 - 8,4)9,0 (2,1 - 10,5)12,31415,5
Power consumptionkW1,76 (0,83 - 2,11)2,27 (1,06 - 2,77)9,0 (2 ~ 10)3,954,52
EER / SEER (7)3,95 / 5,303,91 / 5,603,78 / 5,673,54 / 5,923,43 / 6,05
Heating (2)CapacitykW7,2 (1,6 ~ 8,4)9,0 (2,1 ~ 10)13,215,417
Power consumptionkW1,76 (0,83 ~ 2,11)2,27 (1,06 ~ 2,77)3,474,164,77
COP / SCOP (7)4,09 / 3,903,97 / 3,83,8 / 4,113,7 / 3,963,56 / 3,83
Rated currentA18,503,97 / 3,803,8 / 3,903,7 / 3,863,56 / 3,64
ConnectivityConnectable capacity%45 - 13045 - 13045 - 13045 - 13045 - 130
Max. number of interiors45667
CompressorBrandMitsubishi ElectricMitsubishi ElectricMitsubishi ElectricMitsubishi ElectricMitsubishi Electric
TypeDC Inverter - RotaryDC Inverter - RotaryDC Inverter - RotaryDC Inverter - RotaryDC Inverter - Rotary
ModelTNB220FLHMCTNB220FLHMCTNB306FPGMCTNB306FPGMCLNB42FSCMC
Quantity11111
FanTypeDCDCDCDCDC
Quantity11222
ModelWZDK170-38G-1WZDK170-38G-1WZDK100-38GWZDK100-38GWZDK100-38G
Flow ratem3/h5.5005.5006.0006.0006.000
Sound pressure (3)dB(A)5657575757
DimensionsNet (W x H x D)mm990 x 966 x 336990 x 966 x 336900 x 1327 x 320900 x 1327 x 320900 x 1327 x 320
Gross (W x H x D)mm1120 x 1015 x 4351120 x 1015 x 4351030 x 1456 x 4351030 x 1456 x 4351030 x 1456 x 435
WeightNetKg75,575,59595100
GrossKg85,585,5106106111
RefrigerantType / GWPR410A / 2088R410A / 2088R410A / 2088R410A / 2088R410A / 2088
Quantitykg / TCO2eq2,95 / 6,162,95 / 6,163,3 / 6,893,9 / 8,143,9 / 8,14
Pipe lengh (4)Max. Heighm2020202020
Totalm100100100100100
Pipe connections (5)Liquidmm9,52 (3/8")9,52 (3/8")9,52 (3/8")9,52 (3/8")9,52 (3/8")
Gasmm15.9 (5/8")15.9 (5/8")15.9 (5/8")15.9 (5/8")19.1 (3/4")
Electrical connections (6)Power cable / Fusemm2 / A2 x 6 + T / 252 x 6 + T / 302 x 6 + T / 302 x 10 + T / 402 x 10 + T / 40
Comunication cablemm23 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)
Working temperature rangeCoolingºC-15 to 43-15 to 43-15 to 43-15 to 43-15 to 43
HeatingºC-15 to 27-15 to 27-15 to 27-15 to 27-15 to 27

ModelMVD-V120W/DRN1MVD-V140W/DRN1MVD-V160W/DRN1MVD-V180W/DRN1MVD-V200W/DRN1MVD-V224W/DRN1MVD-V260W/DRN1
CodeCL23265CL23266CL23267CL23268CL23269CL23270CL23271
Power supply3N-, 400V, 50Hz3N-, 400V, 50Hz3N-, 400V, 50Hz3N-, 400V, 50Hz3N-, 400V, 50Hz3N-, 400V, 50Hz3N-, 400V, 50Hz
Cooling (1)CapacitykW12,31415,517,52022,426
Power consumptionkW3,253,954,525,36,16,87,6
EER / SEER (7)3,78 / 5,673,54 / 5,923,43 / 6,053,30 / 5,133,28 / 5,583,29 / 6,073,42 / 5,43
Heating (2)CapacitykW13,215,417192224,528,5
Power consumptionkW3,474,164,7756,15,96,8
COP / SCOP (7) 3,80 / 3,903,70 / 3,863,56 / 3,643,80 / 3,863,61 / 3,644,15 / 3,744,19 / 3,76
Rated currentA10,0011,0012,0012,5014,5016,2018,70
ConnectivityConnectable capacity%45 - 13045 - 13045 - 13045 - 13045 - 13045 - 13045 - 130
Max. number of interiors6679101112
CompressorBrandMitsubishi ElectricMitsubishi ElectricMitsubishi ElectricMitsubishi ElectricMitsubishi ElectricMitsubishi ElectricMitsubishi Electric
TypeDC Inverter - RotaryDC Inverter - RotaryDC Inverter - RotaryDC Inverter - RotaryDC Inverter - RotaryDC Inverter - RotaryDC Inverter - Rotary
ModelTNB306FPNMCTNB306FPNMCLNB42FSAMCLNB42FSAMCLNB42FSAMCLNB53FCAMCLNB53FCAMC
Quantity1111111
FanTypeDCDCDCDCDCDCDC
Quantity2222222
ModelWZDK100-38GWZDK100-38GWZDK100-38GWZDK100-38GWZDK170-38-G-1WZDK170-38-G-1WZDK170-38-G-1
Air flow ratem3/h6.0006.0006.0006.80010.99910.49410.494
Sound pressure (3)dB(A)57575759595960
DimensionsNet (W x H x D)mm900 x 1327 x 320900 x 1327 x 320900 x 1327 x 320900 x 1327 x 3201120 x 1558 x 4141120 x 1558 x 4141120 x 1558 x 414
Gross (W x H x D)mm1030 x 1456 x 4351030 x 1456 x 4351030 x 1456 x 4351030 x 1456 x 4351270 x 1720 x 5651270 x 1720 x 5651270 x 1720 x 565
WeightNetKg9595102107137146,5147
GrossKg103103113118153165,5163
RefrigerantType / GWPR410A / 2088R410A / 2088R410A / 2088R410A / 2088R410A / 2088R410A / 2088R410A / 2088
Quantitykg / TCO2eq3,3 / 6,893,9 / 8,143,9 / 8,144,5 / 9,44,8 / 10,026,2 / 12,956,2 / 12,95
Pipe lengh (4)Max. Heighm20202020202020
Totalm100100100100120120120
Pipe connections (5)Liquidmm9.52 (3/8")9.52 (3/8")9.52 (3/8")9.52 (3/8")9.52 (3/8")9.52 (3/8")9.52 (3/8")
Gasmm15.9 (5/8")15.9 (5/8")19.1 (3/4")19.1 (3/4")19.1 (3/4")19.1 (3/4")22.2 (7/8")
Electrical connections (6)Power cable / Fusemm2 / A4 x 4 + T / 254 x 4 + T / 254 x 4 + T / 254 x 4 + T / 254 x 6 + T / 304 x 6 + T / 304 x 10 + T / 40
Comunication cablemm23 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)3 x 0,75 (shielded)
Working temperature rangeCoolingºC-15 to 43-15 to 43-15 to 43-15 to 43-15 to 43-15 to 43-15 to 43
HeatingºC-15 to 27-15 to 27-15 to 27-15 to 27-15 to 24-15 to 24-15 to 24

ModelMVD-V400W/DRN1MVD-V450W/DRN1
CodeCL23272CL23273
Power supplyF, V, Hz3N-, 400V, 50Hz3N-, 400V, 50Hz
Cooling (1)CapacitykW4045
Power consumptionkW11,913,6
EER / SEER (7)3,35 / 5,083,32 / 5,03
Heating (2)CapacitykW4550
Power consumptionkW11,112,7
COP / SCOP (7)4,05 / 3,513,93 / 3,45
Rated currentA33,0044,00
ConnectivityConnectable capacity%45 - 13045 - 130
Max. number of interiors1414
CompressorBrandMitsubishi ElectricMitsubishi Electric
TypeDC Inverter - RotaryDC Inverter - Rotary
ModelLNB42FSAMCLNB53FCAMC
Quantity22
FanTypeDCDC
Quantity22
ModelWZDK560-38G(B)WZDK560-38G(B)
Flow ratem3/h16.57516.575
Sound pressure (3)dB6262
DimensionsNet (W x H x D)mm1360 x 1650 x 5401460 x 1650 x 540
Gross (W x H x D)mm1450 x 1785 x5601550 x 1785 x560
WeightNETKg240275
GrossKg260290
RefrigerantType / GWPR410A / 2088R410A / 2088
Quantitykg / TCO2eq9,0 / 18,7912,0 / 25,06
Pipe lengh (4)Max. Heighm2020
Totalm250250
Pipe connections (5)Liquidmm (pulg.)12,7 (1/2")12,7 (1/2")
Gasmm (pulg.)22,2 (7/8")25,4 (1")
Electrical connections (6)Power cable / Fusemm2 / A4 x 25 + T / 704 x 35 + T / 90
Comunication cablemm23 x 0,75 (shielded)3 x 0,75 (shielded)
Working temperature rangeCoolingºC-5 a 43-5 a 43
HeatingºC-15 a 24-15 a 24

Notes:

(1) Nominal cooling conditions: Indoor 27 °C DB, 19 °C WB and outdoor 35 °C DB, pipe length of 5 m and a height difference of 0 m.

(2) Nominal heating conditions: Indoor 20 °C DB, 15 °C WB and outdoor 7 °C DB, pipe length of 5 m and a of height difference of 0 m.

(3) Noise level measured in semi-anechoic chamber at 1m distance front and 1 m high.

(4) Pipes distances when outdoor unit is installed upper than the indoor units. Otherwise the maximum distance in vertical can reach 30 m.

(5) Pipe diameter are of stop valves, this does not mean that the pipe should be this diameter.

(6) Power wiring recommended for L < 20 m, for longer distances will be calculated.

(7) Data measured under EUROVENT EN 14825 conditions, at 100% simultanity