Industrial range
The new system Maxi MVD VR4+ (3 pipes) allows heating and cooling different areas simultaneously with a single HVAC system. Which saves up to 50 % in energy costs compared to a conventional 2 pipe system.
The system consists of five basic modules that can be combined among them, allowing maximum power up to 180 kW and maximum pipe length up to 1000 m.
Model | MVD-252(8)W/D2RN1T(C) | MVD-280(10)W/D2RN1T(C) | MVD-335(12)W/D2RN1T(C) | MVD-400(14)W/D2RN1T(C) | MVD-450(16)W/D2RN1T(C) | |||
---|---|---|---|---|---|---|---|---|
Code | CL23115 | CL23116 | CL23117 | CL23118 | CL23119 | |||
Power supply | 3N-, 400V, 50Hz | 3N-, 400V, 50Hz | 3N-, 400V, 50Hz | 3N-, 400V, 50Hz | 3N-, 400V, 50Hz | |||
Cooling (1) | Capacity | kW | 25,2 | 28 | 33,5 | 40 | 45 | |
Power consumption (7) | kW | 5,97 | 6,75 | 9,28 | 11,49 | 14,20 | ||
EER (7) | 4,22 | 4,15 | 3,61 | 3,48 | 3,17 | |||
Heating (2) | Capacity | kW | 27 | 31,5 | 37,5 | 45 | 50 | |
Power consumption (7) | kW | 5,02 | 6,21 | 9,24 | 9,76 | 11,90 | ||
COP (7) | 5,38 | 5,07 | 4,06 | 4,10 | 3,78 | |||
Current | A | 20,8 | 22,1 | 22,8 | 31,8 | 32,8 | ||
Connectivity | Connectable capacity | % | 50 - 130 | 50 - 130 | 50 - 130 | 50 - 130 | 50 - 130 | |
Max. number of interiors | 13 | 16 | 20 | 23 | 26 | |||
Compressor | Brand | Hitachi | Hitachi | Hitachi | Hitachi | Hitachi | ||
Type | DC Inverter | DC Inverter | DC Inverter | DC Inverter | DC Inverter | |||
Quantity | 1 | 1 | 1 | 2 | 2 | |||
Model No. 1 | E655DHD-65D2YG | E655DHD-65D2YG | E655DHD-65D2YG | E655DHD-65D2YG | E655DHD-65D2YG | |||
Model No. 2 | -- | -- | -- | E405DHD-36D2YG | E405DHD-36D2YG | |||
Fan | Type | DC | DC | DC | DC | DC | ||
Quantity | 2 | 2 | 2 | 2 | 2 | |||
Flow rate | m3/h | 12.000 | 12.000 | 13.000 | 15.000 | 15.000 | ||
Static pressure | Standard | Pa | 0-20 | 0-20 | 0-20 | 0-20 | 0-20 | |
Sound pressure (3) | dB(A) | 57 | 57 | 58 | 60 | 60 | ||
Dimensions | Net (W x H x D) | mm | 1250 x 1615 x 765 | 1250 x 1615 x 765 | 1250 x 1615 x 765 | 1250 x 1615 x 765 | 1250 x 1615 x 765 | |
Gross (W x H x D) | mm | 1305 x 1790 x 820 | 1305 x 1790 x 820 | 1305 x 1790 x 820 | 1305 x 1790 x 820 | 1305 x 1790 x 820 | ||
Weight | Net | Kg | 255 | 255 | 255 | 303 | 303 | |
Gross | Kg | 273 | 273 | 273 | 322 | 322 | ||
Refrigerant | Type / GWP | R410A / 2088 | R410A / 2088 | R410A / 2088 | R410A / 2088 | R410A / 2088 | ||
Quantity | kg / TCO2eq | 10 / 20,88 | 10 / 20,88 | 10 / 20,88 | 13 / 27,14 | 13 / 27,14 | ||
Pipe distances (4) | Max. Vertical | m | 70 | 70 | 70 | 70 | 70 | |
Total | m | 1.000 | 1.000 | 1.000 | 1.000 | 1.000 | ||
Pipe connections (5) | Liquid | mm | 12.7 (1/2") | 12.7 (1/2") | 15.9 (5/8") | 15.9 (5/8") | 15.9 (5/8") | |
Gas at high pressure | mm | 19.1 (3/4") | 19.1 (3/4") | 19.1 (3/4") | 22.2 (7/8") | 22.2 (7/8") | ||
Gas at low pressure | mm | 22,2 (7/8) | 22,2 (7/8) | 25.4 (1) | 28,6 (1 1/8") | 28,6 (1 1/8") | ||
Gas balance | mm | 19.1 (3/4") | 19.1 (3/4") | 19.1 (3/4") | 19.1 (3/4") | 19.1 (3/4") | ||
Oil balance | mm | 6 (1/4") | 6 (1/4") | 6 (1/4") | 6 (1/4") | 6 (1/4") | ||
Electrical connections (6) | Power cable / Fuse | mm2 / A | 4 x 6 + T / 25 | 4 x 6 + T / 25 | 4 x 6 + T / 25 | 4 x 16 + T / 35 | 4 x 16 + T / 35 | |
Comunication cable | mm2 | 3 x 0,75 (shielded) | 3 x 0,75 (shielded) | 3 x 0,75 (shielded) | 3 x 0,75 (shielded) | 3 x 0,75 (shielded) | ||
Working temperature range | Cooling | ºC | -5 to 43 | -5 to 43 | -5 to 43 | -5 to 43 | -5 to 43 | |
Heating | ºC | -20 to 24 | -20 to 24 | -20 to 24 | -20 to 24 | -20 to 24 | ||
Simultaneously | ºC | -5 to 24 | -5 to 24 | -5 to 24 | -5 to 24 | -5 to 24 |
Notes:
(1) Nominal cooling conditions: Indoor 27 °C DB, 19 °C WB and outdoor 35 °C DB, pipe length of 7.5 m and a height difference of 0 m.
(2) Nominal heating conditions: Indoor 20 °C DB, 15 °C WB and outdoor 7 °C DB, pipe length of 7.5 m and a height difference of 0 m.
(3) Noise level measured in semi-anechoic chamber at 1m distance front and 1.3m high.
(4) Refrigeration distances when outdoor unit is higher installed than the indoor units. Otherwise the maximum distance in vertical can reach 110m.
(5) Pipe diameter are of stop valves, this does not mean that the pipe should be this diameter. The oil balance pipe is only needed when two or more modules are connected.
(6) Power wiring recommended for L < 20 m, for longer distances will be calculated.